Facilities
Engine and Emissions Research
Facilities
Engine Emissions Measurement Instrumentation
- Sierra Instruments BG-1 Micro-Dilution Test Stand
- Sartorius M3P Precision Microbalance in an environmental test
chamber (for weighing particulate filters)
- Nicolet Magna 550 FTIR Spectrometer
- Horiba On-Line Gas Analyzers for HC, CO and CO2
- Hewlett Packard 6890 Gas Chromatograph with TCD and FID detectors
- R&P Co., Inc. Series 5100 Diesel Particulate Analyzer
- California Analytical HFID 300 THC analyzer
- LambdaScan Portable Lambda Sensor
Engines
- Yanmar TS180 single-cylinder, naturally aspirated, water-cooled,
indirect injection (IDI) diesel engine, 15 hp rating
- General Motors 6.5 liter V-8 turbodiesel, indirect injection (IDI)
engine
- Volkswagen 1.9 liter "TDI" turbo direct injection (DI)
diesel engine
- Navistar T444E V-8 turbocharged, direct injection (DI) diesel
engine
- Cummins B5.9L 6-Cylinder, direct injection (DI) turbodiesel engine
- Waukesha CFR Octane Rating Engine
Engine Test Cells
50 Hp Clayton CAM-50 water brake dynamometer mounted on a
movable cart and connected to a computerized data acquisition and control system
Two 250 Hp eddy current dynamometer and test stand with
computerized data acquisition and control, and integrated control of coolant and lubricant
temperature
450 Hp eddy current dynamometer mounted in a sound reducing
enclosure and connected to a computerized data acquisition and control system
Exhaust Aftertreatment
- Fixed bed flow reactor for catalyst conversion and
selectivity studies
- Catalytic flow reactor for determination of catalyst
reaction kinetics
Additional Analytical Instrumentation Available to Projects
in the Energy Institute
- HP 5971A gas chromatograph/mass spectrometer tabletop
system
- Waters high performance liquid chromatography system
with photodiode array and UV detectors
- Carlo Erba high resolution gas chromatograph/mass
spectrometer
- A DuPont 490B gas chromatograph/mass spectrometer
fitted with capillary column and interfaced to a CDS Pyroprobe 1000 flash pyrolysis system
- Zeiss optical microscope and a digital image analysis
system
- Several gas chromatographs including Perkin Elmer
models 8500, 3920 and Autosystem GC, and three Hewlett Packard 5890 gas chromatographs
- Chemagnetics M-100 solid-state 13C NMR
spectrometer
- Bruker AMX 360WB NMR system fitted with microimaging
accessory
- Computer Chemical Systems 10000 supercritical fluid
chromatograph
- Carlo Erba 1106 C,H,N,O Elemental Analyzer fitted
with a Perkin Elmer Sigma 10 integrator/recording system
- SEM, TEM, FESEM and XRD equipment in the Materials
Characterization Laboratory and the Materials Research Institute available on a
fee-for-use basis
Schematic Diagram of the Single-Cylinder Engine
Facility

Schematic Diagram of the 450 hp Engine Facility

Digital Photo of the Cummins B5.9 in the 250 hp
Engine Test Stand

Digital Photo of the Navistar T444E V-8
Turbodiesel in the 450 hp Test Cell

Digital Photo of the Yanmar TS-180 Engine with
Kistler CAM Encoder Installed

Digital Photo of the VW 1.9L TDI Engine in the
250 hp Engine Test Stand

Digital Photo of the Waukesha CFR Octane Rating
Engine

Digital Photo of the Faculty/Staff Shuttle that
will be Converted to Operation on Blends of DME and Diesel Fuel

(Peter Tijm of Air Products in foreground; Back from left to right:
Prof. Boehman, Mike Nowak of FETC and John Winslow of FETC)